Custom Search
 
  
 
LO 55-1905-223-12
Notes:
1. Install filters, fill crankcase. Operate at idle and inspect for leaks. Shut off engine, and allow 5 minutes for oil to drain
to crankcase. Check oil level with dipstick.
2. Check crankcase level with engine shutdown.
3. A sample of oil shall be sent to an AOAP Laboratory for analysis at an interval of 100 hours or 90 days for Active Army
and 50 hours or 180 days for USAR/NG. Refer to TB 43-0211 for sampling requirements.
4. When AOAP Laboratory support is not available, drain and refill crankcase at 250 hours or 6 months.
LUBRICANT INTERVAL
INTERVAL
LUBRICANT
S
CAUTION
2000
DO NOT USE MULTI-VISCOSITY
OIL IN THIS GEARBOX
Rotella
Gearbox Oil
Filter (Remove,
Replace)
Gearbox Oil
Rotella
(See Note 6)
Drain (Drain,
(C)
Refill)
(See Note 5)
D
(C)
Rotella
Gearbod Oil
S
Level Dipstick
2000
(Check Level)
(C)
WAV 850 MAIN REDUCTION GEAR
TOTAL TASK-HOURS*
TOTAL TASK-HOURS*
INTERVAL
TASK-HOURS
INTERVAL
TASK-HOURS
S or 2000
1.0
D
0.1
S or 2000
1.0
-KEY-
EXPECTED TEMPERATURES
CAPACITY
INTERVALS
ALL TEMPERATURES
Lubricating oil,
Rotella
D-Daily
10.5 gallons
40W
internal combustion
S-Semiannually
engine, tactical service
(6 months)
Notes:
5. A sample of oil shall be sent to an AOAP Laboratory for analysis at an interval of 100 hours or 90 days for Active Army
and 50 hours or 180 days for USAR/NG. Refer to TB 43-0211 for sampling requirements.
6. There are two filters in the main oil circuit with a changeover lever.
7. When AOAP laboratory support is not available, drain and refill crankcase and remove and replace gearbox oil filter at
2000 hours or 6 months.
Card 2 of 41


 