Custom Search
 
  
 
LO 55-1905-223-12
LUBRICANT INTERVAL
INTERVAL
LUBRICANT
OC
Crankcase Oil
OE/HDO
250
Fill Cap
(See Note 8)
(C)
OE/HDO
Crancase Oil
Level Dipstick
D
(Check Level)
OC
Engine Oil
OE/HDO
(See Note 9)
250
Bypass Filter
(C)
AOAP Analysis
(Remove, Clean,
Replace)
OE/HDO
Engine Oil
(See Note 8)
Filter
OC
(C)
AOAP Analysis
250
(Remove, Clean,
Replace)
(See Note 8)
Crankcase Drain OE/HDO
(C)
(Drain, Fill)
OC
(See Notes 10, 11)
250
(C)
NTA 855-GC SHIP SERVICE GENERATOR SET
TOTAL TASK-HOURS*
TOTAL TASK-HOURS*
INTERVAL
TASK-HOURS
INTERVAL
TASK-HOURS
OC or 250
1.0
D
0.1
OC or 250
1.0
-KEY-
EXPECTED TEMPERATURES
CAPACITY
INTERVALS
ALL TEMPERATURES
Lubricating oil,
OE/HDO
D-Daily
internal combustion
11 gallons
15W/40
(MIL-PRF-2104)
OC-On Condition
engine, tactical service
Notes:
8. Install filters, fill crankcase. Operate at idle and inspect for leaks. Shut off engine, and allow 5 minutes for oil to drain
to crankcase. Check oil level with dipstick.
9. Check crankcase level with engine shutdown.
10. A sample of oil shall be sent to an AOAP Laboratory for analysis at an interval of 100 hours or 90 days for Active Army
and 50 hours or 180 days for USAR/NG. Refer to TB 43-0211 for sampling requirements.
11. When AOAP Laboratory support is not available, drain and refill crankcase at 250 hours or 6 months.
Card 3 of 41


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business