Custom Search
 
  
 
TB 600-1
2.
Perform during operation preventive maintenance checks using the appropriate Technical Manual(s) and DA Form
2404.
3.
Stop the generator set using the appropriate Technical Manual.
4.
Perform after operation preventive maintenance checks using the appropriate Technical Manual(s).
22.
Check each DA Form 2404 for mistakes and make corrections as needed.
(10 minutes)
Point out any steps he/she forgot to do.
23.
Discuss operating procedures peculiar to your unit SOP.
(no time limit)
E.
REVIEW AND TEST:
1.
Before each student takes the test, put five faults on the generator set. Vary the faults for different tests and choose the
five faults from the following.
Gasoline Engine Driven
Diesel Engine Driven
a.
Voltmeter off zero.
a.
Oil level low (drain one
b.
Frequency meter off zero.
quart into a clean
c.
Battery negative cable
container and keep).
disconnected.
b.
Oil dipstick missing.
d.
Missing current selector knob
c.
Air restrictor indicator missing.
(use 5/64 inch allen wrench).
e.
Missing battery caps.
d.
Loose ground wire.
f.
Missing oil dipstick.
e.
Battery negative cable
g.
Loose ground wire.
disconnected.
h.
Loose spark plug cable.
f.
Battery cap missing.
i.
Fuel filter missing.
g.
Shutter box assembly
j.
Air restriction indicator
will not close (cut a small stick
missing.
approximately 2-3/8 inches long and
k.
Positive fuel selector valve
place inside of lower shutter).
in wrong position.
l.
Position oil baffle rod in
wrong position.
h.
Missing voltage adjust
m.
Position air cleaner shutter
knob (use 5/64 inch
in wrong position.
allen wrench).
n.
Position circuit breaker to
i.
Missing master switch
the ON position.
knob (use 5/64 inch
o.
Remove engine cover.
allen wrench).
j.
Position circuit breaker
to the ON position.
Change 3 H-14


 


Privacy Statement - Copyright Information. - Contact Us