Pull engine stop controls (5) all the way out.
CAUTION
Do not start both engines at the same time as this will run down the
batteries.
e.
Set engine circuit switches (6) ON. The engine audible alarm (7) and low oil pressure warning light (9)
should come on. The MK1 and MK2 w/ Saber 5.95 Liter generator warning light (8) should come on. The
MK2 w/ Cummins 5.9 Liter battery parallel light (8) should not come on. Voltmeter (10) should read
25 vdc or more. Turn engine alarm mute switch OFF (11) to stop audible alarm.