CAUTION
Do not start both engines at the same time as this will run down the
batteries.
NOTE
The MK1 and MK2 w/ Sabre 5.95 liter engine has a heat switch on
the instrument panel. The MK2 w/ Cummins 6BT 5.9 liter engine
does not have a heat switch.
h.
Press heat switch (15) and hold for at least 20 seconds.
MK2 W/ CUMMINS 6BT 5.9 LITER
MK2 W/ SABRE 5.95 LITER
12
CAUTION
If engine fails to start after 30 seconds release start switch and let
starter motor cool for two minutes.
i.
While pressing heat switch (15) engage start switch (12) and hold in this position until engine starts
(approximately 10 seconds). Release start switch (12).
NOTE
After engine starts, engine audible alarm will activate again when oil
pressure reaches 20 lb/in2 (1.5 Kp/cm2) pressure. Turn engine
alarm mute switch OFF to stop audible alarm.
CAUTION
After engine starts observe oil pressure gage. If gage does not
register 20 lb/in 2 (1.5 Kp/cm2) pressure within 10 seconds shut
down engine.
j.
After engine starts continue to press heat switch (15) and hold in this position until engine is running
smoothly.
k.
After engine is running smoothly take finger off heat switch (15).
2-60