Custom Search
 
  
 
TM 5-1940-277-10
TM 1940-10/1
Table 3-1. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
SUDDEN LOSS OF POWER (NO BLACK SMOKE).
Step 1.  Check to see if engine stop control (1) is pushed all the way in.
Push in control.
Step 2.
Check to see if fuel system is functioning normally by holding one of the injector tubes (2) between
thumb and forefinger and feeling for a pulsing. Notify unit maintenance.
Step 3.
Check fuel water separators for water in fuel (see page 2-25). Notify unit maintenance.
3.
SUDDEN LOSS OF POWER (HEAVY BLACK SMOKE).
Step 1.  Look to see if air inlet (3) is blocked. Notify unit maintenance.
3
MK2 W/ CUMMINS 6BT 5.9 LITER
Change 3
3-5


 


Privacy Statement - Copyright Information. - Contact Us