Custom Search
 
  
 
TM 5-1940-277-20
TM 1940-20/2
NOTE
Gauge lamp replacement procedure is same for all gauges.
REMOVE: Gauge Lamp
1.
Remove gauge lamp socket (3) by pulling rubber cover and socket free from gauge (4).
2.
Remove lamp by pushing in and turning counterclockwise 1/4 turn.
REPLACE: Gauge Lamp
Insert new gauge lamp into socket (3) by pushing in and turning clockwise 1/4 turn to lock in place.
REMOVE: Gauge
NOTE
Gauge replacement procedure is same for all gauges, only
difference is number of wires to different gauges.
1.
Remove gauge lamp socket (3) (refer to step 1, gauge lamp removal).
2.
Using 7 mm box wrench remove nuts (5) securing washers (6) and wires (7) to gauge terminals.
3.
Hold gauge (4) on front side of panel and remove two knurled nuts (8) and bracket (9).
4.
Remove gauge (4) from front of panel.
3-97


 