TM 5-1940-277-20
TM 1940-20/2
3-87. SLAVE STARTING INSTRUCTIONS.
TOOLS: 10 mm Box Wrench
Terminal/Post Cleaner
Wire Brush
PARTS/MATERIALS: NATO Slave Cable
MK1 NATO Adapter
Distiller Water
Baking Soda
Water
Eye Goggles
Rubber/Protective Gloves
GAA Grease
Rags
Reference: TM 9-6140-200-14
Preparation:
Battery gases can explode. Do not smoke, have open flames, or make sparks
q
around batteries. Batteries always vent gases. Battery can explode and cause in-
jury.
Electrolyte (battery fluid) and battery corrosion can cause injury to you. Wear
q
safety goggles and gloves. Flush clothing and skin with clear water if electro-
lyte or battery corrosion is contacted. See a doctor if on face or in eye.
Read slaving procedure before at-
1.
tempting slave starting.
Open and secure battery hatch (TM
2.
5-1940-277-10).
Disconnect strap (1) securing battery
3.
box cover (2).
Remove battery box cover (2).
4.
NOTE
Correct electrolyte level is at bottom of vent plug holes (filler caps). The electrolyte must
be between top of plates and bottom of vent plug hole for this procedure. Do not overfill
the battery.
Remove battery vent caps (1). Make sure vent holes in bottom of battery vent caps (3) are clean and open so gases
5.
can escape.
3-186


 


Privacy Statement - Copyright Information. - Contact Us