Custom Search
 
  
 
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
87
WEEKLY
Portable
FIRE PUMP
FUEL BOWL. Loosen fingernut (1).
Plugged, leaking
Swing bracket (2) out of way.
or cracked.
Remove bowl (3).
WARNING
Do not smoke or have an open
flame when handling gasoline.
Remove filer nut (4) from stud (5). Remove
filter (6). Clean filer (6) and bowl (3) in
gasoline. Replace gasket (7) if damaged.
Reassemble filter (6), nut (4) and stud (5).
Reassemble bowl (3) and bracket (2).
Tighten fingernut (1).
Change 4 2-137


 