91
BI-WEEKLY
Engine Room
BATTERY. Check the specific gravity of the
Battery electrolyte
electrolytes in the batteries.
low; or specific
gravity reading
In the Pilothouse, remove 12 screws (58)
lower than 1.220.
and cover plate (59).
Replace cover (59) after completion of
servicing.
WARNING
Battery acids are dangerous.
Do not get acids on skin or in
eyes.
Get  medical  help
immediately if you do.
Inspect batteries, cables and battery
Battery electrolyte
terminals. Remove battery clamps from
low; or specific
terminals and clean, using battery cleaning
gravity reading
brush.
lower than 1.220.
Replace battery cables after servicing.