Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
142
QUARTERLY
Anchor Winch
DRIVE BRAKE
Binds or fails to
Compartment
function.
Lubricate fitting (5) located on drive brake
double toggle (6) with grease (MIL-G-24139A
(SH)).
143
QUARTERLY
Anchor Winch
GEAR DRIVE
Low oil level.
Compartment
GEAR HOUSING. Remove breather cap (7).
Drain gear housing (8) by removing pipe plug
(9). Drain into a suitable container.
NOTE
Do not drain oil into bilges. Use
oil separation/recovery system
to collect drained oil.
Replace pipe plug (9). Refill gear housing
with approximately 10 gallons (7.85 l) of oil
(MIL-L-2105D, GO 80/90) through the pipe
nipple for breather cap (7). Replace breather
cap (7).
2-186 Change 4


 