Custom Search
 
  
 
TM 55-1905-219-14-10
5-35. BLOWER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
OVERHAUL - ASSEMBLY (Cont)
g. Blower
1. Install an oil seal
rear end
pilot J6270-5 over
plate (46)
the serrated end of
each rotor shaft.
2. Check the dowel pins.
The dowel pins must
project .270 inch
from the flat inner
face of the rear end
plate to assure pro-
per alignment of the
end plate with the
housing .
3. With the top of the
end plate identified
as in Step 6a and its
flat finished face
towards the blower
housing, slide the
end plate straight
over the oil seal
pilots and start the
dowel pins straight
into the dowel pin
holes in the housing.
Then, push or tap
the end plate against
the housing.
4. Insert the two screws
(44) through the end
plate and thread them
into the housing.
Tighten the screws
securely. Do not use
lockwashers on these
screws.
5. Remove the oil seal
pilots from the rotor
shafts.
5-570


 