TM 55-1905-219-14-2
2-48. ANCHOR WINCH ENGINE-LOCAL-START/STOP-COLD WEATHER (Cont).
n.
Observe the control pressure gage (18) on the hydraulic tank assembly (19). Normal control pressure is 365 to
370 psi (25771.6 to26124.6 gm sq cm). Minimum allowable pressure is 350 psi (24712.5 gm sq cm).
o.
Observe operating pressure gage (20) on hydraulic tank assembly (19). Normal operating pressure is 600 to 800
psi (42364.2 to 56485.6 gm sq cm). Minimum allowable pressure is 600 psi (42364.2 gm sq cm).