2-180. GENERATOR ENGINE - EMERGENCY START. (Cont)
c.
Read pressure gages (6 and 7), they should read:
AMBIENT TEMPERATURE
GAGE READING
Above 40 (4.4 )
F
C
1500 psi (1054.5 kg sq cm)
40 to 0 (4.4 to -17.8 )
F
F
C
C
2500 psi (1757.5 kg sq cm)
Below 0 (-17.8 )
F
C
3300 psi (2319.9 kg sq cm)
If not perform step d.
d.
Operate hand pump (8) on hydrostarter in aft engine room to charge accumulators (9 and 10).
e.
Push in fuel rod knob (11) on hydraulic governor (12).