Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-1. Propulsion Engine - Exhaust Smoke Analysis
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. White Smoke.
Step 1.
Check for faulty injectors.
Replace as necessary. Refer to paragraph 3-15.
Step 2.
Check for low compression. Consult the Hard Starting Table 3-2.
Table 3-2.
Propulsion Engine - Hard Starting
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Engine will not rotate.
Step 1.
Check hydrostarter.
Refer to tables 3-16 through 3-21, and perform the operations listed.
Step 2.
Check for defective starting motor switch in either the pilot house or
engine room.
Replace the starting motor switch. Refer to paragraph 3-25.
Step 3.
Check for internal seizure.
Crank the engine at least one complete revolution. If the engine cannot
be rotated a complete revolution, internal damage is indicated and the
engine must be disassembled to ascertain the extent of damage and
the cause. Refer to paragraph 3-7.
3-23


 


Privacy Statement - Copyright Information. - Contact Us