Table 3-6. Propulsion Engine - Excessive Crankcase Pressure
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Breather restriction.
Step 1.
Check for obstruction or damage to breather.
Clean and repair or replace the breather assembly. Refer to paragraph 3-
32.
3. Air from blower or air box.
Step 1.
Check for damaged blower-to-block gasket.
Replace the blower-to-block gasket. Refer toparagraph 3-12.
Step 2.
Check cylinder block end plate gasket for leaking.
Replace the end plate gasket. Refer to paragraph 3-44.
3-50


 