Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-12. Hydrostarter - Cranking Speed Too Low - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Cranking speed too low (Cont).
LUBRICATING OIL GRADES
DESCRIPTION
SPECIFICATION
OES (Sub Zero)
MIL-L-10295
OE/HDO - 10
MIL-L-2104
OE/HDO - 20
MIL-L-2104
OE/HDO - 30
MIL-L-2104
Step 3.
Check for control valve that is not fully open.
Check the travel of the control valve
located on the side of the starter.
Minimum travel is 1-1/16 inch (2.699 cm).
Remove any obstruction that prevents
sufficient control valve or control
lever handle travel.