Table 3-16. Hydrostarter - Starter Turns but Engine Does Not - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Starter turns but engine does not.
Step 1.
Check for pinion not engaging flywheel ring gear.
Replace as per paragraph 3-46.
Refer to Direct Support
Maintenance.
Step 2.
Check for pinion clutch slipping. Can be
caused by cold weather or heavy lubricant.
Wash out the heavy lubricating
oil and replace it with SAE 5W
or SAE 1OW oil.
Step 3.
Check for overrunning - clutch burned out.
Replace as per paragraph 3-46.
Refer to Direct Support
Maintenance.
Table 3-17. Hydrostarter - Loss of Accumulator Precharge
(Nitrogen) - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of accumulator precharge (nitrogen).
Step 1.
Check for damaged seal ring on piston.
Some nitrogen precharge, but no
fluid pressure in the system,
bubbles and foaming in the reser-
voir indicates that the nitrogen
is leaking past the seal ring on
the accumulator piston. Refer to
Direct Support Maintenance.