Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-31. Hydrostarter - Low or No Accumulator Pressure -
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Engine driven pump fails to raise pressure:
Step 1.
Check for air in system.
To purge the engine driven pump of air:
a.
Operate the engine at maximum
no-load engine speed.
b.
Break the hose connection (1)
on the pressure side of the
engine-driven pump until a
full stream of oil is dis-
charged from the pump.
c.
Connect the hose to the pump
and alternately loosen and
tighten the swivel fitting
(2) on the pressure hose
until the oil leaking out
when the fitting is loose
appears free of air bubbles.
d.
Tighten the swivel fitting
securely and observe the
pressure gage. The pressure
must rise rapidly to the
accumulator precharge pressure
(1250 psi at 70 ) (8274 kPa
F
at 68.4. Then the pressure
)
must increase slowly to 2900
to 3300 psi (19996 to 22754
kPa) in 6 to 10 minutes,
depending upon the size of
the particular accumulator.
3-114


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business