TM 55-1905-219-14-3
Table 3-33. Hydrostarter - Loss of Fluid from Reservoir -
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of fluid from reservoir.
Step 1.
Check for external leaks.
With pressure in the system,
check all hoses and fittings
for leaks. Tighten the fittings.
Refer to Direct Support Maintenance.
Step 2.
Check for worn starter shaft seal.
Remove the starter after releasing
the system pressure. If evidence
of system fluid is found, refer to
Direct Support Maintenance.
Step 3.
Check for defective gasket under starter cover.
Operate the starter. During the
cranking cycle, watch closely for
fluid leaking around cover or any
of the retaining bolts. Refer to
paragraph 3-46.
Step 4.
Check for worn shaft seal.
Refer to Direct Support Maintenance.
3-120


 