Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-42. Generator - Troubleshooting.
of Hand Pump - Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Generator Noisy.
Step 1. Listen for defective bearings.
a.
Check oil level in sightglass - Add oil type
OE/HDO.
b.
Bad bearing - Refer to Direct Support Main-
tenance.
Step 2.
Check for damaged fan.
a.
Inspect fan for cracks, breaks, insufficient
mounting and looseness. Refer to paragraph
3-63.
b.
Inspect mounting of generator to engine -
tighten bolts and refer to paragraph 3-62.
WARING
Be sure generator is off. Tag switchboard to prevent accidental starting.
3. No Output.
Step 1.
Check internal wiring - Burned, broken, worn or
loose.
Tighten loose wire connection.
Insulate worn wires.
Refer all other problems to Direct Support Main-
tenance.
Step 2.
Inspect for defective external wiring.
Refer to Direct Support Maintenance.