Custom Search
 
  
 
TM 11-1905-219-14-3
Table 3-74. Hydrostarter - Loss of Accumulator Precharge
(Nitrogen) - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of accumulator precharge (nitrogen) (Cont.).
Step 3.
Check for damaged seal ring between shell and end cap.
Apply light oil on threaded end of accumulator at end of the cap. Bubbling
of the oil indicates a leak past the end cap seal. Refer to Direct Support
Maintenance.
Table 3-75. Anchor Winch Engine - Hydrostarter Hight Pressure
in System (3500 psi or above) - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. High pressure in system - 3500 psi (24133 kPa) or above.
Step 1.
Check for defective gage.
Refer to Direct Support Maintenance.
Step 2.
Check for engine-driven pump unloading valve not operating properly.
Refer to Direct Support Maintenance.
3-220


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business