Custom Search
 
  
 
TM 55-1905-219-14-4
3-10. VARIABLE SPEED MECHANICAL GOVERNOR - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
Repair (Cont)
g. Governor
Install
One end of
lever
spring is be-
retrac-
hind screw
ting
(6)
spring
(5)
h. Stop
Install.
Do not tighten.
lever
(3),
screw
(65), and
lock-
washer
(66)
i. Stop
Install.
Refer to ad-
justment proce-
dure.
Adjustments
31. Stop
The solenoid plunger can be properly aligned to the
governor stop lever as follows:
a. The bolt through the rod end eye should
be locked to the stop lever and adjusted
to a height that will permit the eye or
clip to float vertically. The clearance
above and below the eye or clip and the
bolt head should be approximately 1/32"
(0.079 cm) minimum.
3-448


 