Custom Search
 
  
 
TM 55-1905-219-14-4
3-47.
ACCUMULATOR - MAINTENANCE INSTRUCTIONS .
a.
The accumulator is a heavy duty shell assembly and piston designed to hold nitrogenpressure for
an extended period of time.
b.
The accumulator is preloaded with nitrogen through a small valve and sealed at the time of
manufacture. A seal ring is in the groove of the piston between two back-up rings prevents the nitrogen from
entering the hydraulic system. The nitrogen is stored in the air valve end of the accumulator and the fluid is
discharged at the opposite end.
c.
A seal ring and back-up ring at each cap prevents escape of fluid and nitrogen from the shell.
Nitrogen is an inert gas. Nitrogen will not rust or corrode the piston or accumulator.
d.
Oil enters the accumulator under pressure from either the engine-driven pump or hand pump and
forces the piston back, compressing the nitrogen, and stores energy to operate the system.
e.
Service replacement accumulators are supplied with a precharge of nitrogen (1250 50 psi (8619
345 kPa)).
This task covers:
a.
Inspection
b.
Replacement
INITIAL SETUP
Test Equipment
Reference
NONE
NONE
Equipment
Special Tools
Condition
Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
NONE
NONE
Personnel Required
General Safety Instructions
1
Observe WARNINGS in this procedure.
3-927


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business