Custom Search
 
  
 
TM 55-1905-219-14-5
3-85. EXHAUST MANIFOLD - MAINTENANCE INSTRUCTIONS.
The one-piece, water cooled exhaust manifold is cast with an integral water jacket surrounding the exhaust
chamber.  The diameter of the exhaust chamber increases uniformly from one end to the other where it
terminates in a flange to which an elbow and flexible exhaust connection is attached. A portion of the engine
coolant is by-passed from the water manifold into the rear end of the jacket surrounding the exhaust manifold
and is discharged from the forward end through a tube into the lower section of the expansion tank. A drain
cock is installed in the bottom of the manifold for draining the water jacket. A plug is provided in the bottom of
the exhaust outlet elbow for draining moisture condensed from the exhaust gases.
This task covers:
a. Removal
c. Repair
b. Inspection
d. Installation
INITIAL SETUP :
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
Para
Torque Wrench
NONE
Material/Parts
Special Environmental Conditions
Gasket kit P/N 5193113
NONE
Personnel Required
General Safety Instructions
2
NONE
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1. Exhaust
a. Drain
Open to drain water.
system
cock
(1)
b. Pipe
Remove to drain water.
plug (2)
3-1432


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business