3-96.4. CYLINDER LINER - MAINTENANC E INSTRUCTIONS (Cont)
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
7. Install the liner in
To reuse the
the proper bore of the
liner, the
cylinder block and
taper must not
measure the inside
exceed .002
diameter at the var-
inch and the-
ious points shown.
out-of-round
Use cylinder bore gage
must not exceed
J5347-01, which has a
.0025
dial indicator call-
inch. In addi-
brated in .0001 inch
tion, the ridge
increments, as it is
formed at the
rather difficult to
top of the ring
obtain accurate
travel must be
measurements with a
removed. If
micrometer. Set the
the out-of-
cylinder bore gage on
round exceeds
zero in master ring
.0025 inch
gage J8386-01. Also
rotate the
check the liner for
liner 90in
taper and out-of-
the block bore
round.
and recheck.