Custom Search
 
  
 
TM 55-1905-219-14-5
3-105. HYDROSTARTER PIPING (FORWARD ENGINE ROOM) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
b. Check fittings and
connections for
tightness and leaks.
6.
Hand pump
Check for leaks.
Refer to para-
(6)
maintenance.
7.
a. Check for leaks.
valve (7)
b. Check fittings. Make
sure they are tight.
8.
Filter and
a. Check for leaks.
gasket (8)
b. Check for cracks,
dents and wear.
9.
Valve ball
a. Check for leaks.
3000 lbs.
(9)
b. Check for cracks,
dents and wear.
c. Check fittings for
tightness.
REPLACE
The oil pressure in this system must be released prior to servicing the
solenoid valve or any other components of the system to prevent possible
injury to personnel or equipment.
NOTE
Release the pressure in the hydrostarter system by opening relief valve on
side of the pump approximately 1/2 turn.
3-1800


 