3-105. HYDROSTARTER PIPING (FORWARD ENGINE ROOM) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPLACE (Cont)
10. Solenoid
Solenoid
a. Clean the exterior
valve
valve
dirt from solenoid
valve and hydraulic
hoses.
b. Disconnect hydraulic
hoses and pipes from
the solenoid valve.
c. Disconnect electrical
wiring from solenoid.
d. Remove bolts and lock-
washers and lift off
solenoid valve.
e. Replace removed
solenoid valve with a
new one.
11. Hand pump
Close the relief valve on
the hand pump.
3-1802


 