Custom Search
 
  
 
TM 55-1905-219-14-6
3-118. TORQUE COUPLING - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
d.
Hubs
1. Insert spacer bar
a. Insert bar
(11
equal in thickness
to same
and
to normal gap .1250
depth at 90
13)
inches (.0318 cm),
intervals.
between the two hubs
(11 and 13).
b. Measure
clearance
between bar
and hub face
with feelers.
c. The differ-
ence in
minimum
.0625 in.
(.0159 cm)
and maximum
.1875 in.
(.0476 cm)
must not
exceed the
angular
limit speci-
fied (.005
in. (.013
cm).
2. Use straight edge to
a. Place
check offset align-
squarely on
ment.
Both hubs at
90inter-
vals.
b. Check with
feelers.
c. Clearance
must not
exceed the
offset limit
.005 in.
(.013 cm).
3-2028


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business