Custom Search
 
  
 
TM 55-1905-219-14-6
3.137.6. DIRECTIONAL VALVE - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
CLEANING
3.
All parts must be thoroughly cleaned and kept clean during inspection and assembly. Contamination in
the unit will cause excessive wear, leakage and decreased service life. Clean in accordance with
standard procedures for hydraulic parts. Do not use compressed air to dry parts unless the air is
completely filtered in order to remove water and contaminants.
INSPECTION
4.
General
a. Internal
Check that they are
passages
clean and unobstructed.
b. Mating
Inspect for nicks and
surfaces
burrs.
c. Threaded
Inspect for wear.
parts
and
holes
5.
Spool
Inspect for scoring and wear. Minor
(9)
scratches can be removed with crocus
cloth. Do not round off sharp corners
of spool bands.
6.
Body
Inspect the body bore for scoring and
(21)
wear. If excessive wear or scoring is
evident on the spool, the body bore is
most likely damaged. Any excess clear-
ances between the spool and body will
increase the leakage of the valve. The
maximum clearance is 0.0012 inch
(0.0030 cm).
3-2260


 