3-205. HYDRAULIC CUB PUMP UNIT - MOTOR CONTROLLER - MAINTENANCE
INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
2. Push down on double
contact bridge and
rotate it 1/4 turn.
3. Remove the bridge.
4. Spring beneath the
bridge can be re-
placed after the
bridge is removed.
e. Coil
1. Remove plunger.
2. Pull down on two
verticale guides;
one in front, and
one in back of coil.
REPLACEMENT
3.
a. Wiring
Tag and disconnect
all wiring.
b. Case
Remove from bulkhead.
3-3194


 