Custom Search
 
  
 
TM 55-1905-219-14-8
4-5. GENERAL (Continued).
Table 4-18. Washer/Dryer Troubleshooting (Continued.)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5.
Fill hose out of place.
Check placement of fill hose from water valve through dryer base pan
and secured in clamp. Slots should be facing tub. Adjust or replace as
necessary.
10.
Wash water not hot enough, controls set for hot wash.
Step 1.
Water from water heater not hot enough or water heater not of sufficient
capacity.
Check the temperature of the water at the water heater. Best washing
results are obtained with water temperatures at 140 to 160F (60C).
If the water temperature at the heater is below 140, inform the user. If
the water temperature at the heater is correct, check for exceptionally
long run of water pipe between heater and washer.
Step 2.
Cold water leaking through the water valve.
Make necessary repairs to the water valve.
Step 3.
Inoperative water temperature selector switch.
Check switch continuity. Replace the faulty switch if necessary.
Step 4.
Hot and cold inlet hose reversed.
Connect hose to water valve correctly.
Step 5.
Water temperature selector switch or water valve solenoids wired incorrectly.
Check wiring to be as shown in wiring diagram.
Step 6.
Screen in the hot water hose connection of the water valve stopped up.
Clean the valve inlet screens.
4-69


 


Privacy Statement - Copyright Information. - Contact Us