Custom Search
 
  
 
TM 55-1905-219-14-8
4-7.5A. PRIMING PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
c. Gasket sur-
Inspect surface for
Smooth out
faces
nicks, burrs, and
minor nicks,
scratches, and
burrs with fine
emery cloth.
d. Shaft seals
Inspect for signs of
leaking or excessive
wear.
Inspect if they feel
rough when rotated.
f. Vanes
Inspect for signs of
If height is
excessive wear.
less than 1/2
inch (.127 cm)
discard.
REASSEMBLY
5. Priming
a. End plate
Place in press with
pump
(32)
counterbore up.
4-339


 