Custom Search
 
  
 
TM 55-1905-219-14-8
4-18.1. SEWAGE AIR PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
ASSEMBLY
8. Oiling
a. Pipe nipple
Install.
system
(9), and
tank (8)
b. Union (7)
Reassemble.
c. Automatic
Install and assemble
oilers (4,
adapters (2) and con-
5, and 6)
nectors (3).
9. Inlet
a. Top (14),
Install.
filter
and pipe
assembly
nipple (15)
b. Union (13)
Reconnect.
c. Filter bag
Install.
holder (11)
d. Gasket
Install.
(12), and
jar (10)
NOTE
Turn the rotor shaft assembly on the cylinder head
shaft end of pump body and check for any binding or
rubbing that may be caused by damaged or misaligned
components.  Correct any such condition by straight-
ening misaligned parts and replacing damaged components.
The pump is now ready to be put into operation.
SERVICE
10. Sewage
a
Oil
Fill tank (8) to level
Use oil OE/HDO-
air pump
on sight glass (32).
30-non deter-
gent.
b. Pipe plug
Replace.
(28)
c. System
1.
Operate.
2.
Recheck oil level.
4-702


 


Privacy Statement - Copyright Information. - Contact Us