Custom Search
 
  
 
TM 55-1905-219-14-9
4-35.3. THERMAL EXPANSION VALVE - AIR CONDITIONING - MAINTENANCE INSTRUCTIONS
(Continued).
The heat interchanger is a shell and tube heat exchanger connected in the main suction and liquid lines near
the compressor. Within the interchanger, the cold suction gas is used to cool the warm liquid refrigerant. This
results in greater system capacity and efficiency. A liquid line bypass valve is usually provided to isolate the
interchanger should either: (a) a liquid leak develop into the suction line, or (b) the compressor discharge gas
temperature rises above 240 (115. 6 ).
F
C
This task covers:
a. Inspection
b. Replace
INITIAL SETUP:
Test Equipment
References
Paragraph
NONE
4-28r
Leak Detection
Tubing Maintenance
Equipment
Special Tools
Condition Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
NONE
NONE
Personnel Required
General Safety Instructions
1
Observe safety precautions in
paragraph 4-28d .
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Heat
a. Tubing
Inspect for breaks,
inter-
cracks, dents, and leaks.
changer
(1)
b. Heat
Inspect for breaks,
inter-
cracks, dents, and leaks.
changer
4-962


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business