4-64.1. TANK LEVEL INDICATION-RECEIVER-MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
ADJUSTMENTS AND ALIGNMENTS (Cont)
meter, remove the face frame and glass, and make a pencil mark at the location of the meter needle. Do not
replace the frame and glass until the completion of meter adjustment procedures.
(4) Full-scale Deflection Adjustment.
Following the performance of the zero adjustment, perform the full-scale deflection adjustment on
receiver modules, proceed as follows:
(a) Hold the ON-OFF-FULL REF toggle :switch on the front panel of the receiver module in
the FULL REF position.
(b) Using a screwdriver, adjust the CALIBRATE control to the setting that causes deflection
to the full scale mark.
(c) Release the ON-OFF-FULL REF toggle switch to the OFF position.
c.
Fluid Level Calibration.
Following the performance of zero and full-scale deflection adjustments, the marking for intermediate
tank fluid levels is accomplished. One of two types of calibration procedures (dry-tank or liquid-in tank) are
employed either to make the marks or to