5-21. HYDROSTARTER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
ASSEMBLY- CONTINUED
5.
a. Bendix
Install.
drive ( 4)
b. Pinion gear
Install.
housing (3)
c. Screws (1),
Install.
and lock-
washers (2)
d. Open control valve to full open
position, allowing accumulator to
discharge completely. (Hydraulic
pressure gauge should now read
"0" psi).
DO NOT disconnect any lines until hydraulic pressure is
completely exhausted.  Remove hydrotor from test circuit.
Drain remaining quantity of oil from hydrotor and close all
openings with suitable plugs to prevent entrance of foreign
matter during storage or shipment.