5-22. ACCUMULATOR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (Cont.)
5. Remove retaining ring
segments (11 and 12).
6. Loosen the 5/8 inch
hex swivel nut (13)
on valve assembly (14).
7. Turn counterclockwise
1-1/2 times.
8. Depress air valve cap
(15) to release any
remaining nitrogen
pressure.