Custom Search
 
  
 
TM 55-1905-220-14-10
5-32. GENERATOR (40 KW) - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY
a. Stator
Install eyebolt (38) and
and coil
other mounting hardware
assembly
in stator and coil frame
(37)
assembly (39).
b. Rotating
1. Install.
coils
(36), and
2. Torque bolts as follows:
bolts (35)
Bolt
lb ft
Nm
3/8
35
47.5
7/16
80
108.5
1/2
110
149.1
5/8
250
339.0
3/4
350
474.5
3. Balance
If new rotating coil assemblies are installed, rebalance the
rotating field and exciter armature assembly to less than 1
ounce-inch.
4. Stake bolts.
5. Insulate.
Use insulat-
ing varnish.
NOTE
The next step is when the horizontal reassembly method is
used.
c. Rotating
1. Install.
field, and
shaft
2. Use two hoists and
assembly
leather or canvas
(34)
slings, and pipe.
5-508


 