5-148. MILK DISPENSER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
SERVICE (Cont)
5. Electrical system checkout.
NOTE
Before final reassembly and installation of the dispenser, check the electrical system for proper
operation as follows: (see figure below).
a.  The electrical system on the hermetic compressor can be checked thoroughly with an ordinary test
lamp as follows:
b. With compressor plugged in, test lamp across following must
light.
(1)
L1 and L2. If no light, check power source.
(2)
L and 3. If no light, make sure control contacts are
closed.
(3) M and 3. If no light, relay circuit is open. Replace relay.
5-1556


 