Custom Search
 
  
 
TM 55-1905-220-14-2
2-49.
ANCHOR WINCH ENGINE-LOCAL-START/STOP-COLD WEATHER (Cont).
n.
Observe the control pressure gage (18) on the hydraulic tank assembly (19). Normal control pressure is 365
to 370 psi (25771.6 to26124.6 gm sq cm). Minimum allowable pressure is 350 psi (24712. 5 gm sq cm).
o.
Observe operating pressure gage (20) on hydraulic tank assembly (19). Normal operating pressure is 600 to
800 psi (42364.2 to 56485.6 gm sq cm). Minimum allowable pressure is 600 psi
2-414


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business