Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-6. Propulsion Engine - Excessive Crankcase Pressure
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Excessive exhaust back pressure.
Step 1.
Check for excessive muffler resistance.
Check the exhaust back pressure and repair or replace the muffler if an obstruction is found.
Refer to Direct Support Maintenance.
Step 2.
Check for faulty exhaust piping.
Check the exhaust back pressure. Refer to Direct Support Maintenance.
Table 3-7. Propulsion Engine - Low Oil Pressure Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Make checks with minimum water outlet temperature of 160F (71C).
o
o
An alarm will sound in the pilot house.
1.
Lubricating oil.
Step 1.
Check for suction loss.
Check the oil and bring it to the proper level on the dipstick.
Step 2.
Check lubricating oil viscosity.
Use the recommended grade and viscosity of oil.
3-49


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business