TM 55-1905-220-14-3
Table 3-17.
Hydrostarter - Loss of Accumulator Precharge (Nitrogen) Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss of accumulator precharge (nitrogen) (Cont).
Step 4.
Check for defective safety fuse.
Replace safety fuse assembly after releasing all nitrogen pressure. Refer to Direct
Support Maintenance.
Table 3-18. Hydrostarter - High Pressure in System (3500 psi or above) Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
High pressure in system - 3500 psi (24133 kPa) or above.
Step 1.
Check for defective gage.
Refer to Direct Support Maintenance.
Step 2.
Check for engine driven pump unloading valve not operating properly.
Refer to Direct Support Maintenance.
3-72


 