Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-22.
Generator Engine - Exhaust Smoke Analysis Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Black or gray smoke caused by -excessive fuel or irregular fuel distribution.
Step 1.
Check for improperly timed injectors and improperly positioned injector rack control
Time the fuel injectors. Refer to paragraph 3-87.
3-78


 