Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-46.
Bow Ramp Winch Brake Troubleshooting.
NOTE
Refer to paragraph 3-120 for all maintenance.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Brake does not release.
Step 1.
Check for power failure.
Check circuit breakers and fuses.
Step 2.
Check for broken or damaged parts.
Replace.
Step 3.
Check electrical connections.
Tighten or replace.
Step 4.
Check manual release.
Check that it is not stuck.
Step 5.
Check for damaged pressure plate assembly.
Replace if magnetic coils are burned or charred.
Step 6.
Check for excessive magnetic gap.
Readjust gap [max .065 (0.165 cm) min .035 (0.089 cm)].
3-138


 