Table 3-61. Anchor Winch Engine Abnormal Engine Operation
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Lack of power.
Step 1.
Check for improper engine adjustment and gear train timing.
Perform adjustments in paragraph 3-142, 3-154, 3-161, and 3-164, if performance is not
satisfactory.
Check the engine gear train timing. An improperly timed gear train will result in a loss of
power due to the valves and injectors being actuated at the wrong time in the engine's
operating cycle. Refer to paragraph 3-164.
Step 2.
Check for insufficient fuel.
Perform a Fuel Flow Test and, if less than 0.8 gallons per minute with engine at 1200 RPM is
returning to the fuel tank, consult the No Fuel or Insufficient Fuel table 3-62.
REMOVE PLUG AND INSTALL CONNECTOR AND PIPE.