Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-64. Anchor Winch Engine Excessive Crankcase
Pressure Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
Air from blower or air box.
Step 1.
Check for damaged blower-to-block gasket.
Replace the blower-to-block gasket. Refer to paragraph 3-144.
Step 2.
Check cylinder block end plate gasket for leaking.
Replace the end plate gasket. Refer to paragraph 3-173.
4.
Excessive exhaust back pressure.
Step 1.
Check for excessive muffler resistance.
Check the exhaust back pressure and repair or replace the muffler if an obstruction is
found. Refer to Direct Support Maintenance.
Step 2.
Check for faulty exhaust piping.
Check the exhaust back pressure. Refer to Direct Support Maintenance.
3-198


 