Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-71. Anchor Winch Engine - Hydrostarter Loss of Fluid
Pressure When Engine is Not Running Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss of fluid pressure when engine is not running (Cont).
Step 2.
Check for engine driven pump check valves not holding.
Disconnect the return hose and inlet hose from the engine-driven pump. Leakage from
the inlet fitting means that both check valves are defective. Leakage at the return fitting
means that only the outlet check valve is defective. Replace the defective check valve
assembly(s). Refer to paragraph 3-178.
Step 3.
Check hand pump valves for not holding.
Disconnect the inlet hose from the hand pump. Leakage from the inlet fitting means that
either the relief valve alone or both the inlet and outlet check valves are defective.
Stone and clean the ball seats in the pump body and replace the balls and springs if
necessary. Refer to paragraph 3-179.
Step 4.
Check for damaged seal ring in starter control valve shown by external leakage.
Refer to Direct Support Maintenance.
Step 5.
Check for external leakage in system.
Examine all hoses and fittings for leaks. Tighten. Refer to Direct Support Maintenance.
Step 6.
Check for loss of accumulator precharge (nitrogen).
3-212


 