Custom Search
 
  
 
TM 55-1905-220-14-5
3-62.1. GENERATOR (12VDC) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
b. Through
Insert through field
Tighten.
bolts
frame.
(21) and
lockwash-
ers (22)
NOTE
Make sure the armature is free to rotate before the
brushes are placed against the commutator.
28.
Brushes
a. Brushes
Lift arm and insert
(20)
brushes.
1.
If new brushes
and
are too long,
brush
the commutator
arms
ends should be
(19)
sanded until
each is, short-
ened enough
for the spring
tension arm to
be properly lo-
cated on top
of the brushes.
Do not file or
notch the top
of the brushes.
2.
Be sure the
brush leads are
bent so that
they will fol-
low the brushes
as they wear
shorter.
3.
Be sure they do
not rub against
any part of the
armature.
b. Screws
Install wiring.
(17) and
lock-
washers
(18)
3-1097


 