Custom Search
 
  
 
TM 55-1905-220-14-5
3-106. HYDROSTARTER PIPING (AFT ENGINE ROOM) - MAINTENANCE
INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1.
Hydro-
a. Check all pipes for
starter
leaks, damage, dents,
piping
cracks or breaks.
(1)
b. Check all pipe fit-
tings. Make sure
they are tight and
do not leak.
2.
Hand
a. Check for leaks.
Refer to para-
pump (2)
graph 3-104.
for maintenance.
3.
Suction
a. Check for leaks.
Refer to para-
filter
graph 3-107. for
(3)
b. Check fittings.
maintenance.
Make sure they
are tight.
4.
Shut-off
a. Check for leaks.
valves
(4)
b. Check for cracks,
or wear.
c. Check fitting for
tightness.
5.
Relief
a. Check for leaks.
valve
(5)
b. Check for cracks,
wear or dents.
c. Check fittings
for tightness.
6.
Sight glass
a. Check for leaks.
with valves
(6)
b. Check glass for
cracks or breaks.
c. Check valves for
wear, cracks, or
dents.
3-1786


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business